{
  "url": "https://proudtek.com/products/rfid-labels/rfid-cryogenic-specimen-label/",
  "sourceUrl": "https://proudtek.com/products/rfid-labels/rfid-cryogenic-specimen-label/",
  "title": "RFID Cryogenic Specimen Labels — LN2 −196 °C Rated",
  "description": "RFID cryogenic labels survive liquid nitrogen storage (−196 °C immersion + vapour phase), ultra-low freezers (−80 °C), autoclave (+121 °C) and 100+...",
  "kind": "product",
  "imageUrl": "https://proudtek.com/landing-images/rfid-cryogenic-specimen-label.jpg",
  "imageAlt": "RFID cryogenic label on a specimen vial for ultra-low temperature sample tracking",
  "imageGallery": [
    {
      "url": "https://proudtek.com/landing-images/rfid-cryogenic-specimen-label.jpg",
      "alt": "RFID cryogenic label on a specimen vial for ultra-low temperature sample tracking"
    }
  ],
  "breadcrumbs": [
    {
      "name": "Home",
      "url": "https://proudtek.com/"
    },
    {
      "name": "Products",
      "url": "https://proudtek.com/products/all/"
    },
    {
      "name": "RFID Cryogenic Specimen Labels — LN2 −196 °C Rated",
      "url": "https://proudtek.com/products/rfid-labels/rfid-cryogenic-specimen-label/"
    }
  ],
  "summary": [],
  "faq": [
    {
      "question": "Does the label stay attached in liquid nitrogen?",
      "answer": "Yes. Our cryogenic adhesive is specifically formulated for extreme cold bonding. The label maintains permanent adhesion at −196 °C in both immersion and vapour-phase liquid nitrogen storage. The adhesive also maintains bond through repeated freeze-thaw cycles (tested 100+ cycles from −196 °C to +37 °C). For best results, apply the label to a clean, dry vial at room temperature before freezing."
    },
    {
      "question": "Can the RFID chip be read through frost?",
      "answer": "Yes. RFID uses radio waves, not optics, so frost, ice and condensation on the vial surface do not affect read performance. This is a major advantage over barcode labels, which become unreadable when obscured by frost. The NFC reader must be within 2-3 cm of the vial for reliable reads through frozen containers."
    },
    {
      "question": "Is the label compatible with automated biobank systems?",
      "answer": "Yes. Our cryogenic RFID labels are compatible with major automated biobank storage and retrieval systems (Hamilton BiOS, LiCONiC, Brooks BioStore). The labels are sized to fit standard cryovial formats (1.5 mL, 2 mL, 5 mL) and do not interfere with automated picking mechanisms. Contact us with your specific system model for confirmed compatibility."
    },
    {
      "question": "How does RFID cryogenic labelling support ISBER best-practice biobank quality management?",
      "answer": "ISBER (International Society for Biological and Environmental Repositories) Best Practices (currently 5th edition, 2023) Section G on Facility Storage, Section J on Inventory Management and Section K on Sample Identification establish the quality-system framework that ProudTek cryogenic labels are designed to satisfy. Specifically: (a) per-sample unique identifier that remains human-readable AND machine-readable through the specimen's storage lifetime (Section K.2) — the RFID layer satisfies machine-readable, the printed 1D / 2D barcode on the same label face satisfies human-readable; (b) chain-of-custody audit trail capturing every custody transfer and storage-location change (Section J.3) — the RFID reader events are timestamped and user-authenticated into the biobank LIMS (LabVantage BioBanking, Hamilton BioStudio, BSI Systems, Thermo Fisher Nautilus, OpenSpecimen); (c) environmental-condition logging for the sample's entire lifecycle (Section G.4) — the RFID events interleave with the freezer's temperature-monitoring data (TempTrak, Cooper Atkins SensoScientific, Dickson DicksonOne) to build the complete audit record. The combined ProudTek label + biobank LIMS + environmental monitoring stack is typically presented to CAP and ISO 20387 accreditation inspectors as the documented quality-system proof."
    },
    {
      "question": "Do the labels survive the IVF and reproductive medicine workflow requirements including HFEA / FDA Part 1271 traceability?",
      "answer": "Yes. IVF and reproductive medicine have the most demanding specimen-traceability requirements in any cryo workflow because misidentification is catastrophic and regulator-unforgiving. Our labels are qualified against the specific IVF workflow stress points: the vitrification step (rapid plunge from 37 °C to −196 °C in seconds, with warming equally rapid), repeated LN2 immersion over 10-30+ year embryo storage horizons, ethanol / ProNova-style disinfection wipes, and the small 0.25 mL / 0.5 mL straw format that dominates reproductive cryopreservation (in addition to the larger 1.5 / 2.0 mL cryovial formats). UK HFEA (Human Fertilisation and Embryology Authority) Code of Practice 9th edition, FDA 21 CFR Part 1271 HCT / P regulations and EU Directive 2004/23/EC on tissues and cells (replaced by EU Reg 2024/1938 SoHO) all require continuous per-sample chain-of-custody with witnessed identification checks at every critical handoff — RFID supplements (does not replace) the witnessed visual check at transfer, thaw and embryo transfer steps. For the highest-risk workflow moments we recommend pairing the RFID cryo label with a second independent identifier (e.g. RFID Witness System from CooperSurgical or Matcher from IMT Matcher) that performs an automatic two-sample identity match before any gamete / embryo handling step proceeds."
    }
  ],
  "procurementFields": [
    {
      "label": "Best fit",
      "value": "Best for asset tagging, packaging, authentication, access control, and smart-label projects."
    },
    {
      "label": "Key options",
      "value": "Form Factor: Adhesive label format for direct application to objects or packaging."
    },
    {
      "label": "Customization",
      "value": "Confirm artwork, encoding, material, chip, and finish requirements before quoting."
    },
    {
      "label": "Quote checklist",
      "value": "Confirm mounting surface, adhesive or on-metal requirements, and expected reading distance. Adhesive label format for direct application to objects or packaging. Share target chip or protocol, quantity, format or size, print or encoding..."
    }
  ],
  "collectionGuidanceFields": [],
  "coreGuidanceFields": [],
  "articleGuidanceFields": [],
  "sourceLinks": [],
  "related": [],
  "productSpecs": [
    {
      "name": "Form Factor",
      "value": "Adhesive label format for direct application to objects or packaging."
    }
  ],
  "machineJsonUrl": "https://proudtek.com/machine/products/rfid-labels/rfid-cryogenic-specimen-label.json",
  "machineTextUrl": "https://proudtek.com/machine/products/rfid-labels/rfid-cryogenic-specimen-label.txt",
  "author": {
    "name": "Proud Tek Co., Limited"
  },
  "publisher": "Proud Tek Co., Limited",
  "credentials": [
    "ISO 9001:2015",
    "ISO 14001:2015",
    "RoHS Compliant",
    "CE Marking",
    "REACH Compliant"
  ],
  "generatedAt": "2026-03-16T01:42:30.697Z"
}